Close

     Fluke Calibration P3000 Pneumatic Deadweight Testers


    This versatile instrument provides calibrations from 1-30 inHg vacuum (0.03-1 bar) and 3-500 psi (0.2-35 bar) in one extremely accurate yet easy to use primary standard. A selector valve converts the unit from pressure to vacuum mode without the need to exchange pistons. Units are manufactured to the highest standards with certified accuracies traceable to International Standards Laboratories such as the National Institute of Standards and Technology (NIST). These piston/cylinder type pneumatic standards provide excellent stability, repeatability and accuracy. An optional built-in hand pump can be added for both pressure and vacuum generation.

Accuracy
Accuracy1±0.015% of reading (±0.008% optional)
1. Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.
Mass and PCU Materials of Construction
Standard weight materialSeries 3 non-magnetic austenitic stainless steel
Weight density7.8 g/cm³
Optional fractional weightsSolution heat treated aluminum
Weight density2.7 g/cm³
Models P3011, P3012, P3013, P3022, P3023, P3025 (V)Piston materialCeramic
Cylinder materialMartensitic steel
Coefficient of expansion11 ppm/°C
Models P3014, P3015, P3025 (P) P3031, P3032 (P & V)Piston materialTungsten carbide
Cylinder materialMartensitic steel
Coefficient of expansion16.5 ppm/°C
Model P3016Piston materialTungsten carbide
Cylinder MaterialTungsten carbide
Coefficient of Expansion11 ppm/°C
General
Test port adaptors1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight24 lbs
Instrument size (W x D x H)17.5 x 12 x 8.5
Mass set weight (typical)65 lbs
Minimum Standard Weight Increments
P3012, P3022 Pressure1 inH2O, (5 mbar)
P3013, P3023 Pressure2 inH2O, (10 mbar)
P3014, P3015, P3025 Pressure1 psi, (0.1 bar)
P3016, P3031, P30321 psi, (0.1 bar)
P3011, P3022, P3023, P3025 Vacuum0.2 inHg (10 mbar)
Optional Fractional Weights
P3014, P3015, P3025 Pressure0.1 psi (0.01 bar)
Built-in Hand Pumps
Pressure modeMax pressure 300 psi (20 bar)
Vacuum modeTo 90% vacuum
Operating Fluid for Liquid Lubricated Models
55-655Mineral oil (standard)
KrytoxFor oxygen-safe applications (optional)
Options
PressCal SoftwareWindows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments.
KrytoxAs operating fluid for liquid lubricated gas operated models.

Fluke Calibration P3000 Pneumatic Deadweight Testers


Fluke P3011-4-P

Fluke Calibration P3011-4-P Pneumatic Deadweight Testers
Vacuum range 3 to 100 kPa
Includes:

P3000 Series Vacuum and Dual Vacuum/Pressure Model
Vacuum operated – single PCU
Built-in pump optional


Fluke P3011-6-P

Fluke Calibration P3011-6-P Pneumatic Deadweight Testers
Vacuum range 30 to 1,000 mbar

Fluke P3011-8-P

Fluke Calibration P3011-8-P Pneumatic Deadweight Testers
Vacuum range 1 to 30 inHg

Fluke P3011-9-P

Fluke Calibration P3011-9-P Pneumatic Deadweight Testers
Vacuum range 30 to 760 mmHg

Fluke P3012-4-P

Fluke Calibration P3012-4-P Pneumatic Deadweight Testers
Pressure range 1.5 to 1000 kPa

Fluke P3012-6-P

Fluke Calibration P3012-6-P Pneumatic Deadweight Testers
Pressure range 15 to 1,000 mbar

Fluke P3012-7-P

Fluke Calibration P3012-7-P Pneumatic Deadweight Testers
Pressure range 400 inH20

Fluke P3013-4-P

Fluke Calibration P3013-4-P Pneumatic Deadweight Testers
Pressure range 3 to 200 kPa

Fluke P3013-6-P

Fluke Calibration P3013-6-P Pneumatic Deadweight Testers
Pressure range 30 to 2,000 mbar

Fluke P3013-7-P

Fluke Calibration P3013-7-P Pneumatic Deadweight Testers
Pressure range 12 to 800 inH2O

Fluke P3014-1-P

Fluke Calibration P3014-1-P Pneumatic Deadweight Testers
Pressure range 0.2 to 10 bar

Fluke P3014-2-P

Fluke Calibration P3014-2-P Pneumatic Deadweight Testers
Pressure range 0.2 to 10 kgf/cm²

Fluke P3014-3-P

Fluke Calibration P3014-3-P Pneumatic Deadweight Testers
Pressure range 3 to 150 psi

Fluke P3014-4-P

Fluke Calibration P3014-4-P Pneumatic Deadweight Testers
Pressure range 20 to 1,000 kPa

Fluke P3014-5-P

Fluke Calibration P3014-5-P Pneumatic Deadweight Testers
Pressure range 0.02 to 1 MPa

Fluke P3015-1-P

Fluke Calibration P3015-1-P Pneumatic Deadweight Testers
Pressure range 0.2 to 35 bar

Fluke P3015-2-P

Fluke Calibration P3015-2-P Pneumatic Deadweight Testers
Pressure range 0.2 to 35 kgf/cm²

Fluke P3015-3-P

Fluke Calibration P3015-3-P Pneumatic Deadweight Testers
Pressure range 3 to 500 psi

Fluke P3015-4-P

Fluke Calibration P3015-4-P Pneumatic Deadweight Testers
Pressure range 20 to 3,500 kPa

Fluke P3015-5-P
Pressure range 0.02 to 3.5 MPa

Fluke P3022-4-P

Fluke Calibration P3022-4-P Pneumatic Deadweight Testers
Pressure range 1.5 to 100 kPa

Fluke P3022-6-P

Fluke Calibration P3022-6-P Pneumatic Deadweight Testers
Pressure range 15 to 1,000 mbar

Fluke P3022-7-P

Fluke Calibration P3022-7-P Pneumatic Deadweight Testers
Pressure range 5 to 400 inH2O

Fluke P3023-4-P

Fluke Calibration P3023-4-P Pneumatic Deadweight Testers
Pressure range 3 to 200 kPa

Fluke P3023-6-P

Fluke Calibration P3023-6-P Pneumatic Deadweight Testers
Pressure range 30 to 2,000 mbar

Fluke P3023-7-P

Fluke Calibration P3023-7-P Pneumatic Deadweight Testers
Pressure range 12 to 800 inH2O

Fluke P3025-1-P

Fluke Calibration P3025-1-P Pneumatic Deadweight Testers
Pressure range 0.2 to 35 bar

Fluke P3025-2-P

Fluke Calibration P3025-2-P Pneumatic Deadweight Testers
Pressure range 0.2 to 35 kgf/cm²

Fluke P3025-3-P

Fluke Calibration P3025-3-P Pneumatic Deadweight Testers
Pressure range 0.2 to 35 kgf/cm²

Fluke P3025-4-P

Fluke Calibration P3025-4-P Pneumatic Deadweight Testers
Pressure range 20 to 3,500 kPa

Fluke P3025-5-P

Fluke Calibration P3025-5-P Pneumatic Deadweight Testers
Pressure range 0.02 to 3.5 MPa