Fluke 729 Automatic Pressure Calibrator
Key Features
- Automatic pressure generation and regulation to 300 psi
- Configure procedures for pressure transmitters and switches
- Measure, source, and simulate 4 to 20 mA signals
- Troubleshoot and calibrate HART smart transmitters
- Automatically document test results
- Applied pressure
- Measured mA, mV, or digital PV
- % error for each test point
Fluke 729 Automatic Pressure Calibrator
Portable automatic pressure calibrator simplifies pressure calibration
The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.
Automatic pressure generation and control
The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point up to 300 psi (20 bar, 2 MPa). Then, internal fine adjustment control automatically stabilizes the pressure at the requested value. You can also fill in a test template and the 729 will automatically pump to and document a multiple-point pressure calibration test at the touch of a button.
The automatic internal fine pressure adjustment can also help compensate for minor leaks in hoses and test setups providing technicians with a stable measurement. No need to manually turn a vernier to compensate for leaks helping to eliminate the hassle of manual pumping and manual fine adjustment of test pressures.
Easy calibration documentation
The Fluke 729 can automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure, the number of test points, and the test tolerance. The 729 does the work for you by documenting and flagging out-of-tolerance test results in red on the graphical display for:
With Fluke Connect® compatibility, the 729 enables a user to perform remote monitoring using the Fluke Connect mobile app to manage and store pressure measurements and logging events. The app even allows for easy sharing so the whole team can access measurements without needing to be in the facility.
Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.
HART communication
Built-in HART communication capabilities enable HART transmitter mA adjustments, HART configuration, and the ability to adjust to applied 0% and 100% values. You can also do configuration tasks such as changing a transmitter tag, measurement units, and ranging. Other supported HART commands include setting fixed mA outputs for troubleshooting, read device configuration, and variables and read device diagnostics.
Rugged, portable design
The 729 is tested and warranted to withstand a 1-meter drop test so it is ready for field instrumentation calibration work. With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them. You can also measure temperature with optional 720RTD probe for performing custody transfer calibrations. A standard semi-rigid carrying case designed for field work, with room in the case to store test hoses, fittings, test leads, and small hand tools means it’s easy to carry everything needed for field pressure calibrations.
Attach one of 50 Fluke 750 Series Pressure Modules to expand the pressure range outside of the internal pump specifications. For greater accuracy and resolution on low pressure calibrations, the Fluke 729 can integrate an external Fluke 750 Series Pressure Module into the test workflow, greatly expanding the calibrators capabilities in low pressure ranges.
Pressure specification* |
One-year specification 0.02% of full scale |
Control specification 0.005% full scale minimum |
*See manual for detailed specifications |
Model | |||||||||
729 30G |
| ||||||||
729 150G |
| ||||||||
729 300G |
| ||||||||
729 30G FC |
| ||||||||
729 150G FC |
| ||||||||
729 300G FC |
| ||||||||
729CN 200K |
| ||||||||
729CN 1M |
| ||||||||
729CN 2M |
| ||||||||
729CN 200K FC |
| ||||||||
729CN 1M FC |
| ||||||||
729CN 2M FC |
| ||||||||
729JP 200K |
| ||||||||
729JP 1M |
| ||||||||
729JP 2M |
| ||||||||
729JP 200K FC |
| ||||||||
729JP 1M FC |
| ||||||||
729JP 2M FC |
|
Electrical specification | |
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range. | |
Ranges | |
mA measure, source and simulate | 0 mA to 24 mA |
Volts dc measure | 0 V dc to 30 V dc |
Resolution | |
mA dc source, simulate and measure | 1 μA |
Voltage dc measurement | 1 mV |
Accuracy | 0.01% ±2 LSD all ranges (at 23 °C ±5 °C) |
Stability | 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C |
mA simulate external voltage requirement | 12 V dc to 30 V dc |
Loop compliance voltage | 24 V dc @ 20 mA |
mA simulate external voltage requirement | 12 V dc to 30 V dc |
Temperature measurement only/100 Ω Pt(385) RTD | -50 °C to 150 °C (-58 °F to 302 °F) |
Temperature resolution | 0.01 °C (0.01 °F) |
Temperature accuracy | ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory) |
Drive capability | 1200 Ω without HART resistor, 950 Ω with internal HART resistor |
Mechanical specification | |
Size (HxWxL) | 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in) |
Weight | 6.5 lbs., 2.95 kg |
Ingress protection | IP54 |
Environmental specification | |
Operating temperature | -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control |
Operating temperature with battery | -10 °C to 40 °C |
Battery will only charge to 40 °C | |
Storage temperature | -40 °C to 60 °C |
Operating altitude | 3000 m |
Storage altitude | 13000 m |
Wireless (729 FC only) | |
Radio frequency certification | FCC ID: T68-FBLE IC:6627A-FBLE |
Wireless radio frequency range | 2412 MHz to 2462 MHz |
Fluke 729 Automatic Pressure Calibrator
FLK-729 30G
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, no wireless communicationUPC: 095969840422
FLK-729 150G
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, no wireless communicationUPC: 095969840415
FLK-729 300G
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, no wireless communicationUPC: 095969840408
FLK-729 30G FC
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, includes wireless communication for Fluke ConnectUPC: 095969840330
FLK-729 150G FC
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, includes wireless communication for Fluke ConnectUPC: 095969840323
FLK-729 300G FC
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, includes wireless communication for Fluke ConnectUPC: 095969840316
FLK-729CN 200K
UPC: 095969840361
FLK-729CN 1M
UPC: 095969840354
FLK-729CN 2M
UPC: 095969840347
FLK-729CN 200K FC
UPC: 095969840279
FLK-729CN 1M FC
UPC: 095969840262
FLK-729CN 2M FC
UPC: 095969840255
FLK-729PLUS 2M
UPC: 095969866439
FLK-729PLUS 1M
UPC: 095969866446
FLK-729PLUS 200K
UPC: 095969866453
FLK-729JP 200K
UPC: 095969840392
FLK-729JP 1M
UPC: 095969840385
FLK-729JP 2M
UPC: 095969840378
FLK-729JP 200K FC
UPC: 095969840309
FLK-729JP 1M FC
UPC: 095969840293
FLK-729JP 2M FC
UPC: 095969840286
FPC1S-FLUKE729-1
Premium Care 1-Year Standard Plan for Fluke 729
FPC3S-FLUKE729-1
Premium Care 3-Year Standard Plan for Fluke 729
Manuals (7)
- 729/729 FC | Users manual
- 729/729 FC | Statement of memory volatility
- 729/729 FC | Quick reference guide
- 729/729 FC | Calibration manual
- 729/729 FC | Calibration manual supplement
- 729/729 FC | Safety sheet
- Radio Frequency Data Class B | Instruction sheet
Data sheet (1)
Application Note (3)
- Four common PRESSURE CALIBRATION PAIN POINTS
- Power facility reduces pressure maintenance costs with the Fluke 729 Automatic Pressure Calibrator
- Research lab reduces process control pressure calibration time by 40%