    Product overview: Fluke 712B RTD Calibrators

    Fluke 712B RTD Calibrator provides highly accurate, easy-to-use, single-function RTD temperature calibration

    Fluke 712B RTD Calibrator is a handheld, battery-operated instrument that measures and sources a variety of RTD types and resistances. It also includes an isolated channel to measure 4-20 mA while sourcing a temperature signal. It offers configurable 0% and 100% source settings for quick 25% linearity checks. It also provides linear ramp and 25% step auto ramp functionality based on 0% and 100% settings.

    Add to that dual inputs, an easy-to-view backlit display, plus the ability to memorize settings at power down for easy restart make the 712B the ideal test tool for temperature calibration professionals who want a highly accurate, easy-to-use, single-function RTD temperature calibrator.

    Other useful features:

    • Dual inputs and backlit display for easy interpretation of measurements
    • Remembers power-down settings to easily restart tests when powered up
    • Provides linear ramp and 25% step auto ramp based on 0% and 100% settings
    • Provides one-year and two-year specifications and traceable certification of calibration

Specifications: Fluke 712B RTD Calibrators

General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals30 V
Operating temperature-10°C to 50°C
Storage temperature-30°C to 60°C
Operating altitude2,000 m
Storage altitude12,000 m
Relative humidity (% RH operating without condensation)Noncondensing
90% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
(Without condensation)
Vibration requirementsMIL-T-28800E, Class 2
Drop text requirements1 m
IP RatingIEC 60529: IP52
Electromagnetic environmentIEC 61326-1, Portable
SafetyIEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L)52.5 x 84 x 188.5 mm
Weight515 g
DC mA Measurement
Resolution0-24 mA
Range0.001 mA
Accuracy (% of reading + counts)0.010% + 2 μA
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C)
Ohms Measurement
Ohms rangeAccuracy (% of reading +counts)
0.00 Ω to 400.00 Ω0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω0.015% + 0.5 Ω
Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications.
Temperature coefficient±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C)
Ohms Source
Ohms range1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Excitation current from measurement device0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts)0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Resolution0.00 Ω to 400.00 Ω0.01 Ω
400.0 Ω to 4000.0 Ω0.1 Ω
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms
RTD Input and Output
RTD Type (α)Range (°C)Measure (°C)Source (°C)
1-year2-yearSource current1-year2-year
10 Ω Pt (385)-200 to 100°C1.5°C3°C1 mA1.5°C3°C
100 to 800°C1.8°C3.6°C1 mA1.8°C3.6°C
50 Ω Pt (385)-200 to 100°C0.4°C0.7°C1 mA0.4°C0.7°C
100 to 800°C0.5°C0.8°C1 mA0.5°C0.8°C
100 Ω Pt (385)-200 to 100°C0.2°C0.4°C1 mA0.2°C0.4°C
100 to 800°C0.015%
+0.18°C
0.03%
+0.36°C
1 mA0.015%
+0.18°C
0.03%
+0.36°C
200 Ω Pt (385)-200 to 100°C0.2°C0.4°C500 μA0.2°C0.4°C
100 to 630°C0.015%
+0.18°C
0.03%
+0.36°C
500 μA0.015%
+0.18°C
0.03%
+0.36°C
500 Ω Pt (385)-200 to 100°C0.3°C0.6°C250 μA0.3°C0.6°C
100 to 630°C0.015%
+0.28°C
0.03%
+0.56°C
250 μA0.015%
+0.28°C
0.03%
+0.56°C
1000 Ω Pt (385)-200 to 100°C0.2°C0.4°C250 μA0.2°C0.4°C
100 to 630°C0.015%
+0.18°C
0.03%
+0.36°C
250 μA0.015%
+0.18°C
0.03%
+0.36°C
100 Ω Pt (3916)-200 to 100°C0.2°C0.4°C1 mA0.2°C0.4°C
100 to 630°C0.015%
+0.18°C
0.03%
+0.36°C
1 mA0.015%
+0.18°C
0.03%
+0.36°C
100 Ω Pt (3926)-200 to 100°C0.2°C0.4°C1 mA0.2°C0.4°C
100 to 630°C0.015%
+0.18°C
0.03%
+0.36°C
1 mA0.015%
+0.18°C
0.03%
+0.36°C
10 Ω Cu (427)-100 to 260°C1.5°C3°C1 mA1.5°C3°C
120 Ω Ni (672)-80 to 260°C0.15°C0.3°C1 mA0.15°C0.3°C
50 Ω Cu (427)-180 to 200°C0.4°C0.7°C1 mA0.4°C0.7°C
100 Ω Cu (427)-180 to 200°C0.2°C0.4°C1 mA0.2°C0.4°C
YSI40015 to 50°C0.2°C0.4°C250 μA0.2°C0.4°C
1. Sensor inaccuracies not included.
2. Resolution: 0.1°C.
3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications.
4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range).
5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source.
6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.

Models: Fluke 712B RTD Calibrators

Fluke 712B

Fluke 712B RTD Calibrator

Includes:

  • Magnetic hanging tool
  • Batteries
  • Manual
  • Traceable calibration certificate
  • Test Leads

Manuals + resources: Fluke 712B RTD Calibrators
Manuals (9)
712B | Users Manual
712B | Users manual supplement
714B | Users Manual
714B | Users manual supplement
712B | Quick reference guide
712B/714B | Statement of memory volatility
712B/714B | Calibration Manual
712B/714B | Safety sheet
714B | Quick reference guide

Compatible accessories: Fluke 712B RTD Calibrators
Probes (1)
Fluke 5627A-9-J Industrial RTD Probe