Fluke 902 FC True-RMS HVAC Clamp Meter
Key Features
- A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
- Offers 200 µA DC measurements to measure flame rod
- Extends resistance range to measure thermistors up to 60kΩ
- Captures flue gas temperature
- Measures start and run motor capacitors
- Measures variable frequency drive performance
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy-to-read backlit display improves readings in low-light settings
- Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
- Measures AC to 600 A and AC and DC voltage to 600 V
- Measures capacitance to 1000 µF and DC to 200 µA
- Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
- Offers True-RMS voltage and current measurements to accurately measure non-linear signals
- Measures resistance to 60 kΩ
- Offers Min/Max recording to capture variations automatically
- Runs on two AA alkaline batteries
Product overview: Fluke 902 FC True-RMS HVAC Clamp Meter
Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site.
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.
Part of the Fluke Connect wireless family
As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real-time with other colleagues with ShareLive™ video calls or email.
The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.
Other useful features:
Specifications: Fluke 902 FC True-RMS HVAC Clamp Meter
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A > 1.4 MIN@600 A Add 2% for CF>400 A | |
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) | |
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) | |
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 600 V / CAT IV 300 V IEC 61010-2-033: CAT III 600 V / CAT IV 300 V | |
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
Models: Fluke 902 FC True-RMS HVAC Clamp Meter
FLK-902 FC
Fluke 902 FC True-rms HVAC Clamp Meter
Includes:
- TL75 test leads (1 pair)
- 80BK integrated DMM temperature probe (1)
- AA alkaline batteries (2)
- Soft carrying case
- User's manual
Resources: Fluke 902 FC True-RMS HVAC Clamp Meter
Manuals (2)
902 FC | Users Manual
374 FC/375 FC/376 FC/902 FC | Calibration Manual
Accessories: Fluke 902 FC True-RMS HVAC Clamp Meter
Cases and holsters (4)
Fluke C33 Soft Carrying Case
Fluke C550 Tool Bag
Fluke TPAK ToolPak™ Magnetic Meter Hanger
Fluke C1600 Tool Hard Case
Test leads, probes and clips (10)
Fluke AC220 SureGrip™ Alligator Clips
Fluke AC285 SureGrip™ Alligator Clips
Fluke AC87 Heavy Duty Bus Bar Clip Set
Fluke AC89 Heavy Duty Insulation Piercing Test Clip
Fluke TL220 SureGrip™ Industrial Test Lead Set
Fluke TL223 SureGrip™ Electrical Test Lead Set
Fluke TL224 SureGrip™ Insulated Test Leads
Fluke TL71 Premium Test Lead Set
Fluke TL75 Hard Point™ Test Lead Set
Fluke TP1 Slim Reach Test Probes
Lights (2)
Fluke LVD1A Non-Contact Voltage Tester with LED Flashlight
Fluke L206 Deluxe LED Hat Light
Adapters and cables (1)
Fluke 80AK-A Thermocouple Adapter
Probes (1)
Fluke 80PK-8 Pipe Clamp Temperature Probe