Close

    Product overview: Fluke 805 FC Vibration Meter

    The reliable, repeatable, accurate way to check bearings and machine health

    Make go or no-go maintenance decisions with confidence. The Fluke 805 FC Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration, bearing health, and machine health.

    Manage and monitor workflow for better maintenance results

    Using the Fluke Connect Mobile App it’s now easier than ever to manage your vibration screening workflow. Integrated machine profile functionality allows you to set up machine profiles using the app and then push them directly to your 805 FC Vibration Meter. Users can then use the list of machine profiles to create work orders, and develop route-based maintenance schedules which can be dynamically sent to technicians in the field, helping to ensure the proper focus on critical assets. Once a machine is tested, the 805 FC communicates the results directly to the app and associates them with the proper profile and route. This data can easily be shared between teams, so you can make better maintenance decisions.

    Other useful features:

    • Reliable, repeatable, accurate device for checking bearings and overall vibration
    • Features innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
    • Provides consistent data quality at both low and high-frequency ranges
    • Offers a four-level severity scale to assess the urgency of problems and bearing condition
    • Allows you to export data via USB or wirelessly, through the Fluke Connect® mobile app
    • Compatible with Fluke Connect® Mobile App that can transmit measurements to your smartphone to be shared in real-time
    • Enables you to get authorization to take the next steps in an instant if machine health is at risk via the Fluke Connect™ mobile app*
    • Allows you to view trending in Microsoft® Excel using pre-built templates
    • Measures overall vibration (10 Hz to 1,000 Hz) for acceleration, velocity, and displacement units of measurement for a wide variety of machines
    • Provides Crest Factor+ technology for reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
    • Compares vibration levels with ISO-10816 severity scales and stores results to the Fluke Connect Cloud
    • Features colored lighting system (green, red) and on-screen comments to indicate how much pressure needs to be applied to take measurements
    • Measures temperature with Spot IR Sensor to increase diagnostic capabilities
    • Holds and saves up to 3,500 measurements in on-board memory
    • External accelerometer (optional) support for hard-to-reach locations
    • Features built-in flashlight for viewing measurement locations in dark areas
    • Provides a large high-resolution display for easy navigation and viewing

Specifications: Fluke 805 FC Vibration Meter

Specifications
Low-frequency range (overall measurement)10 Hz to 1,000 Hz
High-frequency range (CF+ measurement)4,000 Hz to 20,000 Hz
Severity levelsGood, satisfactory, unsatisfactory, unacceptable
Vibration limit50 g peak (100 g peak-peak)
A/D converter16-bit
Signal-to-noise ratio80 dB
Sampling rateLow frequency: 20,000 Hz
High frequency: 80,000 Hz
Real-time clock backupCoin battery
Sensor
Sensitivity100 mV g ± 10%
Measurement range0.01 g to 50 g
Low-frequency range (overall measurement)10 Hz to 1,000 Hz
High-frequency range4,000 Hz to 20,000 Hz
Resolution0.01 g
AccuracyAt 100 Hz ± 5% of the measured value
Amplitude Units
Accelerationg, m/sec²
Velocityin/sec, mm/sec
Displacementmils, mm
Infrared Thermometer (Temperature Measurement)
Range-20 °C to 200 °C (-4 °F to 392 °F)
Accuracy±2 °C (4 °F)
Focal lengthFixed, at ~3.8 cm (1.5")
External Sensor
Note: Fluke supports but does not provide external sensors
Frequency range10 Hz to 1,000 Hz
Bias voltage (to supply power)20 V dc to 22 V dc
Bias current (to supply power)Maximum 5 mA
Firmware
External interfacesUSB 2.0 (full speed) communication
Data capacityDatabase on internal flash memory
UpgradeThrough USB
MemoryUp to 3,500 measurements
Radiated Emission
Electrostatic discharge: burstStandard EN 61000-4-2
Electromagnetic interferenceStandard EN 61000-4-3
REStandard CISPR 11, Class A
Environmental
Operating temperature-20 °C to 50 °C (-4 °F to 122 °F)
Storage temperature-30 °C to 80 °C (-22 °F to 176 °F)
Operating humidity10% to 95% RH (non-condensing)
Operating/storage altitudeSea level to 3,048 meters (10,000 feet)
IP ratingIP54
Vibration limit500g peak
Drop test1 meter
General Specifications
Battery typeAA (2) Lithium Iron Disulfide
Battery life250 measurements
Size (L x W x H)24.1 cm x 7.1 cm x 5.8 cm
(9.5 in x 2.8 in x 2.3 in)
Weight0.40 kg (0.89 lb)
ConnectorsUSB mini-B 7-pin, external sensor jack (SMB connector)

Models: Fluke 805 FC Vibration Meter

Fluke 805 FC

Fluke 805 FC Vibration Meter

Includes:

  • USB cable
  • Storage case
  • Belt holster
  • Quick reference guide
  • Two (2) AA batteries

Resources: Fluke 805 FC Vibration Meter
Manuals (4)
805/805 FC | Users manual
805/805 FC | Users manual supplement
805/805 FC | Quick reference guide
Radio Frequency Data Class B | Instruction sheet