Fluke 718Ex Intrinsically Safe Pressure Calibrator
Key Features
- ATEX II 1G Ex ia IIC T4 Compliant.
- Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
- Wide range of selectable measurement units for pressure.
- Current measurement with 0.02% accuracy and 0.001 mA resolution.
- Pressure switch test function.
- Min-Max Hold functions.
- Compact size and weight.
- Simple, push-button user interface.
- Rugged and reliable, ideal for field use.
Fluke 718Ex Intrinsically Safe Pressure Calibrator
Pump Up the Pressure
The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a powerful intrinsically safe, self contained pressure calibrator for usage in explosion endangered areas.
Related blog posts:
Calibrating in potentially explosive atmospheres
Pressure Measurement Accuracy | ||
Fluke 718Ex 30G | Range | -830 mbar to 2 bar (internal sensor) Over pressure: 3x FS |
Resolution | 0.0001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex 100G | Range | -830 mbar to 2 bar (internal sensor) Over pressure: 2x FS |
Resolution | 0.001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex 300G | Range | -830 mbar to 20 bar (internal sensor) Over pressure: 375 psi, 25 bar |
Resolution | 0.0001 bar | |
Accuracy | 0.05% FS | |
Functions | Zero, Min, Max, Hold, Damp | |
Fluke 718Ex series | Range | Via pressure module connector 29 pressure modules, 2.5 mbar to 700 bar Over pressure per pressure module specs |
Resolution | Per pressure module specs | |
Accuracy | To 0.025% of full span, per pressure module specs | |
Functions | Zero, Min, Max, Hold, Damp | |
Source pressure, built in pump range | -820 mbar to full scale | |
For use with non-corrosive gasses. Supported Pressure Units psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm², mmHg, inHg Media compatibility per pressure module specs | ||
Technical Data | ||
Measure accuracy | Range | 0-24 mA |
Resolution | 0.001 mA | |
Accuracy | 0.02% rdg ±2 counts | |
Display | LCD, 5 digit pressure and current simultaneous | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% (10°C to 30°C) | |
75% (30°C to 40°C) | ||
45% (40°C to 50°C) | ||
35% (50°C to 55°C) | ||
Operating altitude | 3,000 m max | |
Safety Specifications | ||
Safety | ATEX II 1G Ex ia IIC T4 compliant | |
CSA Certification I.S. Class I | ||
Div 1 Groups A-D , T4 | ||
Mechanical and General Specifications | ||
Size (L x W x H) | 216 x 94 x 66 mm (with holster) | |
Weight | Approx. 992 g (with holster) | |
Warranty | Three years, one year for pump | |
Shock | 1 meter drop test | |
Vibration | Random, 2 G, 5-500 Hz | |
Battery type | One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V | |
Battery life | 4 to 20 hours, depending on functions used |
Fluke 718Ex Intrinsically Safe Pressure Calibrator
Fluke 718Ex 30GFluke 718Ex 30G Intrinsically Safe Pressure Calibrator, 30 psi
Includes:
- Protective red holster
- TL75 test leads
- AC72 test clips
- CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)
- Fluke 718Ex CCD content control drawing
- NIST- traceable calibration report and dat
Fluke 718EX 100G
Fluke 718Ex 100G Intrinsically Safe Pressure Calibrator, 100 psi
Fluke 718EX 300G
Fluke 718Ex 300G Intrinsically Safe Pressure Calibrator, 300 psi
Manuals (7)
- 718Ex | Users manual
- 700PEx | Instruction sheet
- 700PEx | Instruction sheet supplement
- 718Ex | Control drawing
- 718Ex 30/100G | Safety sheet
- 750P/750R, 750PEx | Statement of memory volatility
- 750PEx | Instruction sheet