    The FI-3000 FiberInspector Ultra offers an extensive feature set that makes testing MPO fiber trunks, cassettes, and array cables easy and efficient. The multiple-camera design provides an instant Live View with simple touchscreen gestures to move from full trunk to individual end faces in real-time.  Touch “TEST”, and in seconds, you’ll get an automated PASS/FAIL result compliant with IEC 61300-3-35. Store results on your phone and share them through text messages, or email, or use the industry-leading LinkWare platform to store complete project reports including copper, fiber loss, OTDR, and end face images. Compact, ergonomic design with autofocus makes it comfortable and fast even when you’re testing hundreds of cables or ports.
    “A speck of dust that’s invisible to the human eye can cause intermittent errors or even complete failure on a fiber optic connection. That’s why every fiber must interconnect – even on cables straight from the factory – be inspected before it’s connected.” - Mike Hughes, VP of Product Management, US Conec, a global leader in the development and supply of high-density optical interconnects.

    1. Interchangeable tips support one or two rows of 8, 12, 16, or single UPC or APC connectors
    2. PortBright™ illumination for dark and crowded patch panels
    3. Protective cover with tether
    4. AutoFocus Control
    5. PortBright on/off
    6. LEDs indicate the optional PASS/FAIL results and Wi-Fi connection
    7. Start an automated test without reaching for your Versiv™ Tester or smartphone
    8. Auto-off saves battery life
    9. Ergonomic design comfortable for inspecting cables or ports
    10. Rugged design for constant field usage
    11. USB port for charging Li-Ion battery and connecting to Versiv
Temperature rangeOperating: -10 °C to +45 °C (+14 °F to +113 °F)
 Storage: -10 °C to +60 °C (+14 °F to +140 °F)
Humidity rangeOperating: 0 % to 95 % (32 °F to 95 °F, 0 °C to 35 °C)
 RH non-condensing
 Storage: 0 % to 95 % (95 °F to 113 °F, 35 °C to 45 °C)
 RH non-condensing
AltitudeOperating: 4,000 m (3,200 m with AC adapter)
 Storage: 12,000 m
Vibration2 g, 5 Hz to 500 Hz
Shock1 meter drop test
SafetyIEC 61010-1: Pollution Degree 2
EMCIEC 61326-1: Controlled Electromagnetic Environment; IEC 61326-2-1
 CISPR 11: Group 2, Class A
 USA (FCC): 47 CFR 15 Intentional Radiators: This device complies with part 15 of the FCC Rules.
Endtype SupportSingle Fiber and MPO: 1x8 (8 fibers), 1x12 (8, 10, or 12 fibers), 1x16 (16 fibers), 2x12 (16, 20, or 24 fibers), 2x16 (32 fibers)
Test LimitsIEC 61300-3-35 ED. 2 MM
 IEC 61300-3-35 ED. 2 SM APC
 Document Only
Optional automated Pass/Fail Test TimeLess than 2 seconds per fiber
Camera type5 Megapixel 1/4-inch CMOS sensor
Field of view610 µm x 460 µm
Resolution1 µm
Light sourceLED, >100,000 hr life
Endface illuminationCoaxial blue LED
Port illuminationWhite LED
Battery TypeLithium-ion; 10.8 hour life
Power AdapterInput: 100 to 240 VAC ±10%, 50/60Hz
 Output: 15 VDC, 2 A maximum
 Class II
WirelessOutput power: <100 mW Frequency ranges: 2.4 GHz (2412 MHz to 2462 MHz)
Transmission* 
Dimensions6.625 in x 5.375 in x 2.125 in (168 mm x 137 mm x 54 mm)
 (with no dust cap or adapter tip)
 Length with dust cap: 7.5 in (191 mm)
Weight11.5 oz (326 gm)
 (with dust cap and no adapter tip)
Models
FI-3000
FI-3000TP-UMPO12F
FI-3000TP-UMPO16F
FI-3000TP-AMPO12F
FI2-7300
FI2-7300-NW
FI-3000-NW
Accessories
FI1000-TIP-KIT
FI-3000-Holster
QC-MPO-12/24-1P
QC-MPO-12/24-5P
QC-MPO-16/32-1P
QC-MPO-16/32-5P
FI-3000-1000ADP
FI1000-1.25-UTIP
FI1000-LC-PCTIP
FI1000-1.25APC-TIP
FI1000-LCAPC-PTIP
FI1000-2.5-UTIP
FI1000-2.5APC-UTIP
FI1000-LCAPC-BTIP
FI1000-SCFC-TIP
FI1000-SCAPC-TIP
FI1000-ST-TIP
FI1000-E2KAPC-TIP
FI-500TP-FCF
FI-500TP-LCF
FI-500TP-U25F
FI-500TP-U125F
FI-500TP-ASCF
FI-500TP-ALCF
FI-500TP-A25F
FI-500TP-A125F
FI-500TP-AFCF
FI-500TP-EXTS
QuickClean-1.25-1P
QuickClean-1.25-5P
QuickClean-2.5-1P
QuickClean-2.5-5P
FI1000-ADAPT-60
VERSIV2-M-NW

Product Highlights

Get a Grip on the Most Efficient, Most Complete Inspection Solution

  • Total end face visibility with Live View from full trunk to individual end face
  • Integrates with Versiv™ Cabling Certification System and LinkWare™ Reporting Software for simple operation and documentation or with mobile phones for testing and sharing
  • Optional automated pass/fail results in seconds
  • Multiple Autofocus/Autocentering Camera design for real-time imaging
  • Rugged, ergonomic design with a convenient holster 
  • Supports one or two rows of 8,12,16 or single UPC or APC connectors.