Close

    Measure-and-view, industrial design, necessity for inspection.

    Temperature and humidity are two important items for comfort test of indoor air and environment. The Fluke 972 Series Temperature Humidity Meter can quickly and easily collect accurate humidity and temperature data. It features streamlined industrial design and is comfortable to hold. Simplified buttons require no complicated operations. The selected high-precision sensors ensure that reliable data is collected. The Fluke 972 Series is an indispensable environmental monitoring tool for facility maintenance and engineering technicians, HVAC service contractors, R&D and manufacturing engineers, and professionals involved in indoor air quality (IAQ) assessments.

 972A972B972ES
Detailed Specifications
Sensor TypeInternalInternal + ExternalExternal
Temperature Measurement Range-30.0 ℃ to 65.0 ℃Internal sensor: -30.0 °C to 65.0 °C;
External sensor: -40.0 °C to 99.9 °C
-40.0 °C to 99.9 °C
Temperature Accuracy±0.5 ℃ (-30.0 ℃ to 65.0 ℃)Internal sensor: ±0.5 °C (-30.0 °C to 65.0 °C)
External sensor: ±0.5 °C (-30.0 °C to 65.0 °C);
±0.7 °C (others)
±0.5 °C (-30.0 °C to 65.0 °C);
±0.7 °C (others)
Temperature Resolution0.1 °C
Dew Point TemperatureRangeN/A-40.0 °C to 99.9 °CN/A
ResolutionN/A0.1 °CN/A
Wet Bulb TemperatureRangeN/A-20.0 °C to 60.0 °CN/A
ResolutionN/A0.1 °CN/A
HumidityRange0.0% RH to 99.9% RH
Accuracy±3% RH (≥20.0% RH to ≤80.0% RH @ 25 ℃)
±5% RH (≥1% RH to <20% RH, >80% RH to ≤95% RH @ 25℃)
Unspecified for others
Resolution0.1% RH
Data StorageN/AYes. Up to 99 setsN/A
Display2-line LCD display, with backlightNo
Auto-offPower off after 20 min without any operationN/A
Max/Min/AvgYesYesN/A
Auto Logging ModeN/AYesN/A
General Specifications
TemperatureOperating-30 °C to 70 °C-40 °C to 70 °C
Storage-30 °C to 70 °C, <80% RH (without battery)-40 °C to 70 °C, <80% RH
AltitudeOperating2000 m
Storage12 000 m
Relative HumidityOperating0% RH to 99% RH
Storage<80% RH
Power SupplyBattery Type2 x AAA Batteries
Battery Life1000 hrs for continuous operating, backlight off
SafetyIEC61010-1, Pollution Degree 2
Dimensions (L x W x H)211 × 58 × 40 mm264 × 33 × 28 mm
Weight172 g (body)127 g
Electromagnetic Environment (EMC)IEC 61326-1: Portable, Electromagnetic Environment; IEC 61326-2-2; CISPR 11: Group 1; Class A
Group 1: Equipment intentionally generates and/or uses conductive-coupled RF energy, which is necessary for its internal operation.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
IP RatingIEC 60529: IP30, non-operating


Fluke 972A/972B/972ES

Fluke 972A/972B/972ES Temperature Humidity Meter

 

Fluke 972A Temperature Humidity Meter

Includes

  • The Fluke 972A Temperature Humidity Meter

Fluke 972B Temperature Humidity Meter

Includes

  • The Fluke 972B Temperature Humidity Meter
  • Fluke 972ES external sensor

Fluke 972ES External Temperature/Humidity Sensor

Includes

  • Fluke 972ES external sensor